web-archive-it.com » IT » L » LANDI.IT

Total: 962

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • System's components LPG: AIR/FUEL MIXERS
    to reach us Newsletters Press Area news events press review Landirenzo News LPG MIXER SYSTEM REGULATOR SE 81 SE 81 SIC AIR FUEL MIXERS Mechanical devices that by using the Venturi principle ensure correct air fuel mixing in both stationary and dynamic conditions Each mixer is designed for a specific vehicle in order together with the regulator to optimize both gas and petrol operation back private area newsletter site map

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=18&idprodotto=21 (2016-02-10)
    Open archived version from archive


  • System's components LPG: LAMBDA CONTROL SYSTEM LC01
    equipped with a lambda sensor The LC01 ECU ensures correct air fuel mixture by driving the actuator which doses the gas flow from the regulator to the mixer located on the intake manifold gas flow continuous regulation system LCS LC01 system does not need manual adjustments and it can automatically adapt to the different environmental conditions and use of the vehicles The system consists of the following components 1 COMPUTER LCS LC01 The LCS LC01 computer is defined as a Stand Alone system for the fact it doesnt interact directly with the petrol system ECU but it works in a separate and independent way The computer processes the signals from the lambda sensor the ignition input throttle body angle signal to manage the correct air fuel mixture on each engine working condition by driving the actuator which doses the gas flow at the engine entry The main functions of the LC01 computer are Emulation of the correct signal of lambda sensor A diagnostic and programming system by means of a special Tester Programme to control mixture and conversion optimization Petrol starting with automatic switch over to gas in a period of time depending on the environmental and engine conditions by managing the gas solenoid valve Actuator driving to adjust the mixture Managing of different safety devices when the vehicle runs on gas as for instance a built in system to cut off petrol injection and an electronic safety device that cuts off supply to the LPG natural gas solenoid valves if the engine talls 2 ACTUATOR Electromechanical device which doses the gas capacity by turning a step motor controlled by the computer so as to maintain the correct air fuel mixture on each engine working condition 3 LCS LC01 SWITCH GAUGE Electronic component located inside the interior compartment whose main

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=19&idprodotto=21 (2016-02-10)
    Open archived version from archive

  • System's components LPG: SWITCH/GAUGE MOD. 094M - 094M ECO
    094M 094M ECO An electronic control module whose main functions are Gas petrol selector with 3 positions and gauge for the fuel being used by means of 2 led Gas starting with timed automatic system to enrich the mixture for starting primer the middle position of the switch closes the gas and petrol solenoid valves at the same time Display of the level of gas in the tank by means

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=13&idprodotto=22 (2016-02-10)
    Open archived version from archive

  • System's components LPG: REGULATOR EC 04
    Newsletters Press Area news events press review Landirenzo News LPG MIXER SYSTEM REGULATOR SE 81 SE 81 SIC REGULATOR EC 04 Device with safety valve to reduces the pressure of the LPG and vaporizes it providing a regular gas flow to the engine It is fitted with two LPG pressure reduction stages that provide stability at both high and low pressures The passage of the LPG from liquid to gaseous phase occurs by pressure drop and heat absorption resulting from the connection to the engine coolant system The engine idling gas flow is activated through the gas pipe main flow as a result of the negative pressure generated by the engine It includes an electronic starting device with a built in safety system which closes the gas solenoid valve when the engine stops Regulator type 2 stage reducer with electronic start up device and negative pressure idle Use Vehicular application suitable for vehicles with or whitout catalytic converter fuel injection and carburetor Type of fluid LPG Liquefied petroleum gas Heating Engine cooling circuit liquid Inlet pressure 45 bar First stage adjustment pressure 0 6 bar Power supply 12 V DC Versions EC 04 up to 100 kW back private area

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=20&idprodotto=22 (2016-02-10)
    Open archived version from archive

  • System's components LPG: SWITCH/GAUGE MOD. 100 - SWITCH MOD. 102
    fuel being used by means of 2 led Gas starting with timed automatic system to enrich the mixture for starting primer the middle position of the switch closes the gas and petrol solenoid valves at the same time Display of the level of gas in the tank by means of 5 led SWITCH MOD 102 An electric control module whose main functions are Gas petrol selector with 3 positions and

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=30&idprodotto=23 (2016-02-10)
    Open archived version from archive

  • System's components LPG: REGULATOR RENZOMATIC
    Electronic control device to reduce the LPG pressure and vaporize it allowing a regular flow of gas whenever the engine requires it It is equipped with two LPG reduction stages that allow stability at both high and low pressures The passage of LPG from the liquid to the gas phase takes place by a drop in pressure and by absorption of the heat taken from parts of the regulator heated with the liquid of the engine cooling circuit The flow of gas necessary for engine idling is obtained through the main gas pipe thanks to the vacuum generated by the engine It includes an electric starting device and a mechanical safety system that trips and shuts off the gas solenoid valves if the engine is switched off or stalls Regulator type 2 stages with electric starting device and vacuum controlled idling Use automotive suitable for vehicles with carburettor and fixed engines Type of fluid LPG Liquefied petroleum gas Heating Engine cooling circuit liquid Maximum inlet pressure 45 bar First stage adjustment pressure 0 8 bar Power supply 12 V DC Versions RENZOMATIC up to 100 kW RENZOMATIC Oversize from 100 kW to 193 kW RENZOMATIC Super Oversize over 193 kW

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=31&idprodotto=23 (2016-02-10)
    Open archived version from archive

  • System's components LPG: LPG SOLENOID VALVE
    reach us Newsletters Press Area news events press review Landirenzo News LPG MIXER SYSTEM RENZOMATIC LPG SOLENOID VALVE This device is positioned between the tank and the regulator and cuts off the flow of LPG during petrol operation and with the engine switched off Available in normal and oversize version both equipped with an interchangeable filter for any impurities there may be in the LPG back private area newsletter site

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=16&idprodotto=23 (2016-02-10)
    Open archived version from archive

  • System's components LPG: AIR/FUEL MIXERS
    links how to reach us Newsletters Press Area news events press review Landirenzo News LPG MIXER SYSTEM RENZOMATIC AIR FUEL MIXERS Mechanical devices that by using the Venturi principle ensure correct air fuel mixing in both stationary and dynamic conditions Each mixer is designed for a specific vehicle and together with the regulator and LCS LC01 system provides optimum gas and petrol operation back private area newsletter site map privacy

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=24&idprodotto=23 (2016-02-10)
    Open archived version from archive



  •