web-archive-it.com » IT » L » LANDI.IT

Total: 962

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • System's components METHANE: Landirenzo Omegas 3.0 Electronic Control Unit
    control unit with dedicated aluminium case IP54 designed and built to integrate the electronics of latestgeneration Euro 4 Euro 5 and Euro 6 vehicles offers the possibility of connecting to the vehicle s OBDII On Board Diagnostics II to acquire and monitor the petrol controls to manage gas calibration compensate the variability of the gas quality and composition With Omegas 3 0 it is also possible to verify the connection

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=76&idprodotto=15 (2016-02-10)
    Open archived version from archive


  • System's components METHANE: Landirenzo Omegas 3.0 Switch - Indicator
    Indicator Electronic control module fitted with rings adaptable for an effective integration in all types of dashboard with the following functions gas petrol switch and monitoring of the current fuel in use by means of two LEDs monitoring of gas fuel level tank by means of 5 LEDs of adjustable intensity by the driver The switch is also equipped with an adjustable acoustic signal buzzer which sounds when the system

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=77&idprodotto=15 (2016-02-10)
    Open archived version from archive

  • Installazione gpl: installare un impianto gpl Landi Renzo
    an emergency or for maintenance Depending on the regulations of the market it is destined for there are versions with additional safety devices such as for example the excess flow valve which shuts off or limits gas flow in case of rupture of the gas pipe or systems that convey gas from the tank to outside the vehicle on reaching certain temperatures or pressures VALVE SEAL BOX This seal box is a safety device enclosing the tank valve that conveys any gas leaks to outside the vehicle by means of breather hoses and ventilation holes It is available made of plastic or aluminium REFUELLING VALVE This device installed in the engine compartment between the tank and the regulator includes connection to the refuelling system and a manual ball device to open shut off gas in the case of an emergency or for maintenance Depending on the standards of the market it is destined to there are versions with different refuelling connections Italy New Zealand NGV1 etc During petrol operation and with the engine switched off the flow of natural gas is cut off by the high pressure solenoid valve on the regulator EXTERNAL REFUELLING VALVE This device is installed flush

    Original URL path: http://www.landi.it/layout.jsp?idz=10069&idtp=167&lang=3&idprodotto=15 (2016-02-10)
    Open archived version from archive

  • System's components METHANE: LAMBDA CONTROL SYSTEM LC01
    vehicles equipped with a lambda sensor The LC01 ECU ensures correct air fuel mixture by driving the actuator which doses the gas flow from the regulator to the mixer located on the intake manifold gas flow continuous regulation system LCS LC01 system does not need manual adjustments and it can automatically adapt to the different environmental conditions and use of the vehicles The system consists of the following components 1 COMPUTER LCS LC01 The LCS LC01 computer is defined as a Stand Alone system for the fact it doesnt interact directly with the petrol system ECU but it works in a separate and independent way The computer processes the signals from the lambda sensor the ignition input throttle body angle signal to manage the correct air fuel mixture on each engine working condition by driving the actuator which doses the gas flow at the engine entry The main functions of the LC01 computer are Emulation of the correct signal of lambda sensor A diagnostic and programming system by means of a special Tester Programme to control mixture and conversion optimization Petrol starting with automatic switch over to gas in a period of time depending on the environmental and engine conditions by managing the gas solenoid valve Actuator driving to adjust the mixture Managing of different safety devices when the vehicle runs on gas as for instance a built in system to cut off petrol injection and an electronic safety device that cuts off supply to the LPG natural gas solenoid valves if the engine talls 2 ACTUATOR Electromechanical device which doses the gas capacity by turning a step motor controlled by the computer so as to maintain the correct air fuel mixture on each engine working condition 3 LCS LC01 SWITCH GAUGE Electronic component located inside the interior compartment whose

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=19&idprodotto=24 (2016-02-10)
    Open archived version from archive

  • System's components METHANE: REGULATOR TN 1
    with three natural gas reduction stages that allow stability at both high and low pressures and a high pressure solenoid valve upstream from the first stage The absorption of heat taken from parts of the regulator heated with the liquid of the engine cooling circuit prevents the natural gas freezing during the fall in pressure phase The flow of gas necessary for engine idling is obtained throught the main gas pipe thanks to the vacuum generated by the engine It includes an electronic starting device with a built in safety system that trips and shuts off the gas solenoid valves if the engine is switched off or stalls Regulator type 3 stages with electronic starting device and vacuum controlled idling at negative pressure Use automotive suitable for vehicles with catalytic converter injection carburettor and turbo charger Type of fuel CNG compressed natural gas Heating engine cooling circuit liquid Test pressure 300 bar Inlet pressure 220 bar First stage adjustment pressure 4 bar Second stage adjustment pressure 1 5 bar Power supply 12 V DC High pressure solenoid valve coil power capacity 20W Idling solenoid valve coil power capacity 14W Versions TN 1 B standard up to 100 kW TN 1

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=46&idprodotto=24 (2016-02-10)
    Open archived version from archive

  • System's components METHANE: REGULATOR TN 1 SIC
    stages that allow stability at both high and low pressures and a high pressure solenoid valve upstream from the first stage The absorption of heat taken from parts of the regulator heated with the liquid of the engine cooling circuit prevents the natural gas freezing during the fall in pressure phase The flow of gas necessary for engine idling has a positive pressure from the second stage and is activated by means of a gas pipe separated from the main flow It includes an electronic starting device with a built in safety system that trips and shuts off the gas solenoid valves if the engine is switched off or even stalls Regulator type 3 stages with electronic starting device and idling at negative pressure Use automotive suitable for vehicles with catalytic converter injection carburettor and turbo charger Type of fuel CNG compressed natural gas Heating engine cooling circuit liquid Test pressure 300 bar Inlet pressure 220 bar First stage adjustment pressure 4 bar Second stage adjustment pressure 1 5 bar Power supply 12 V DC High pressure solenoid valve coil power capacity 20W Idling solenoid valve coil power capacity 18W Versions TN 1 B SIC standard up to 100 kW

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=50&idprodotto=24 (2016-02-10)
    Open archived version from archive

  • System's components METHANE: INJECTORS EMULATORS (OPTIONAL)
    Press Area news events press review Landirenzo News CNG MIXER SYSTEM LAMBDA CONTROL SYSTEM REGULATOR TN 1 TN 1 SIC INJECTORS EMULATORS OPTIONAL During gas operation these electronic devices cut off the flow of petrol on cars equipped with electronic injection and emulate the signal of the injectors or other sensors The emulator model for each car varies depending on the type of injection system involved in the conversion back

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=21&idprodotto=24 (2016-02-10)
    Open archived version from archive

  • System's components METHANE: OBD EMULATORS
    Newsletters Press Area news events press review Landirenzo News CNG MIXER SYSTEM LAMBDA CONTROL SYSTEM REGULATOR TN 1 TN 1 SIC OBD EMULATORS During the gas function these electronic devices interact with the diagnostic Ecu emulating the signals that are necessary to avoid the recording of false errors in the control unit In this way the petrol system works in optimal conditions avoiding drift and false errors back private area

    Original URL path: http://www.landi.it/layout.jsp?idz=10068&idtp=166&lang=3&idcomponente=22&idprodotto=24 (2016-02-10)
    Open archived version from archive



  •